Skip to main content

Table 3 Results from the ROC analysis for the diagnosis of PCOS based on different BMIs

From: The reference value of anti-Müllerian hormone to diagnose polycystic ovary syndrome is inversely associated with BMI: a retrospective study

BMI Groups

AUC

P value

The optimal cut-off value of AMH (ng/ml)

Sensitivity (%)

Specificity (%)

BMI < 18.5

(n = 89)

0.931

 < 0.001

5.145

84.3

89.1

18.5 ≤ BMI < 24

(n = 1079)

0.915

 < 0.001

4.345

83.5

84.2

24 ≤ BMI < 28

(n = 904)

0.901

 < 0.001

4.115

81.0

84.2

BMI ≥ 28

(n = 415)

0.885

 < 0.001

3.165

88.7

74.6

Total population

(n = 2487)

0.899

 < 0.001

4.405

78.7

85.6

  1. AMH Anti-Müllerian hormone, BMI Body mass index, AUC Area under the curve