Fig. 4

From: Evaluation of three-dimensional SonoAVC ultrasound for antral follicle count in infertile women: its agreement with conventional two-dimensional ultrasound and serum levels of anti-Müllerian hormone

Fig. 4

Bland-Altman plot comparing agreement between two ultrasounds’ techniques regarding follicular volume. Legend: Agreement between 2D and 3D ultrasounds’ techniques regarding the mean of follicular volume. The lower (−2.78) and upper (2.41) limits of agreements are represented as dotted lines, the formula to obtain them are found in the right side of the image (SD stands for Standard Deviation); the mean difference (−0.18) is represented as a continuous line. Statistical analysis performed through Bland-Altman (p ≥ 0.05; paired t-test)