From: A high sensitivity assay is more accurate than a classical assay for the measurement of plasma CRP levels in endometriosis

Figure 1

ROC of hsCRP and CRP for prediction of moderate-severe endometriosis. A: In an overall analysis (all cycle phases combined). The AUC was significantly higher for hsCRP analysis than for classical CRP analysis for the diagnosis of moderate-severe endometriosis in an overall analysis (all cycle phases combined, p = 0.018). B: In a luteal cycle phase. The AUC values of hsCRP and CRP were not significantly different (p = 0.065). C: In a follicular cycle phase. The AUC was higher for hsCRP analysis than for classical CRP analysis with borderline significance (p = 0.047). D: In a menstrual cycle phase. The AUC values of hsCRP and CRP were not significantly different (p = 0.83).