Skip to main content

Management of long-term and reversible hysteroscopic sterilization: a novel device with nickel-titanium shape memory alloy

Abstract

Background

Female sterilization is the second most commonly used method of contraception in the United States. Female sterilization can now be performed through laparoscopic, abdominal, or hysteroscopic approaches. The hysteroscopic sterilization may be a safer option than sterilization through laparoscopy or laparotomy because it avoids invading the abdominal cavity and undergoing general anaesthesia. Hysteroscopic sterilization mainly includes chemical agents and mechanical devices. Common issues related to the toxicity of the chemical agents used have raised concerns regarding this kind of contraception. The difficulty of the transcervical insertion of such mechanical devices into the fallopian tubes has increased the high incidence of device displacement or dislodgment. At present, EssureĀ® is the only commercially available hysteroscopic sterilization device being used clinically. The system is irreversible and is not effective immediately.

Presentation of the hypothesis

Our new hysteroscopic sterility system consists of nickel-titanium (NiTi) shape memory alloy and a waterproof membrane. The NiTi alloy is covered with two coatings to avoid toxic Ni release and to prevent stimulation of epithelial tissue growth around the oviducts. Because of the shape memory effect of the NiTi alloy, the device works like an umbrella: it stays collapsed at low temperature before placement and opens by the force of shape memory activated by the body temperature after it is inserted hysteroscopically into the interstitial tubal lumen. The rim of the open device will incise into interstitial myometrium during the process of unfolding. Once the device is fixed, it blocks the tube completely. When the patient no longer wishes for sterilization, the device can be closed by perfusing liquid with low temperature into the uterine cavity, followed by prospective hysteroscopic removal. After the device removal, the fallopian tube will revert to its physiological functions.

Testing the hypothesis

Currently, experimental and clinical studies are needed to attest the safety, efficiency and reversibility of the novel sterilization device.

Implications of the hypothesis

If our hypothesis is confirmed, appropriate and reversible contraceptive can be achieved with the device we have designed, which may have significant repercussions for numerous women worldwide.

Background

Hysteroscopic sterilization is a safer option than sterilization through laparoscopy or laparotomy because it avoids abdominal cavity invasion and the use of general anaesthesia. Moreover, this procedure can be performed in an outpatient setting by an incision-free route, with a shorter recovery period, and at a lower cost [1ā€“4]. Scholars around the world devote themselves to the research of new technologies for female sterilization, including methods that involve tubal occlusion, mainly by using chemical agents combined with a sclerosing agent [5], cyanoacrylate [6], n-butyl-2-cyanoacrylate adhesive [7], and polidocanol [8]. Other mechanical devices such as in situ-gelling polymeric device [9], implant with two sets of six slots [10], or intestine submucosal device [11] are also under investigation. The main concerns are related to the toxicity of the chemical agents on the tubal epithelium, peritoneum, and pelvic organs. Additionally, the transcervical insertion of the mechanical device into fallopian tube may be technically challenging, resulting in a high incidence of device displacement or dislodgment [12]. The methods mentioned above are not currently in use in a clinical setting.

Gradually, with the development of material science, shape memory materials (SMMs), including shape memory alloys (SMAs) and shape memory polymers (SMPs), have attracted a lot of attention because of their unique characteristics and super elasticity. SMMs have the capability of ā€œmemorizingā€ and recovering their permanent shape (SP) from an original temporary shape when subjected to an appropriate temperature or other particular stimuli. Therefore, a bulky device could potentially be implanted in a relatively small space in a compressed temporary shape through less invasive surgery. Once in place, it can be expanded to its previously defined size or shape to fit the space as required [13ā€“16]. The application of SMMs for the sterilization purposes, two studies including a SMP device [12] and an oviduct plugs with nickel-titanium (NiTi) shape memory alloy and silicone rubber [17] are under study in animal experiments in China. Additionally, EssureĀ® (Conceptus Incorporated, Mountain View, CA, USA) is a most promising transcervical sterilization device, and its body is made of NiTi shape memory alloy [18]. This system was approved by the US Food and Drug Administration (FDA) in 2002. Currently, it is the only commercially available hysteroscopic sterilization device used in clinical practice, since the AdianaĀ® Permanent Contraception System (Hologic, Inc., Bedford, MA, USA), approved by the FDA in 2009, was removed from the US market by the manufacturer in 2012 [19, 20]. Both EssureĀ® and AdianaĀ® contraception systems were proven efficacious and safe by relatively short-term clinical trial data. Very few pregnancies occurred among women with confirmed bilateral tubal occlusion achieved with both hysteroscopic methods. However, long-term data beyond 7Ā years is unavailable. According to the FDA directions and product labelling, bilateral tubal occlusion must be confirmed 3Ā months after device implantation mainly by performing hysterosalpingogram (HSG). At this time, the fallopian tubes undergo fibrosis, which leads to tubal occlusion and causes the contraceptive effect. Thus, patients must use alternative contraception for at least 3Ā months post procedure. Even at that time, if bilateral tubal occlusion is not confirmed, the patient should continue alternative contraception for 3 additional months. Pregnancies that occurred while either one of these devices was in place were attributed to lack of follow-up, improper use of alternative contraception, failure of alternative contraception, or misinterpretation of HSG results [19ā€“21].

Aside from the lack of immediate effect, another limitation is that both systems approved by FDA are irreversible. In fact, in the United States, the overall cumulative probability of expressing regret within 14Ā years after tubal sterilization was 20.3% for women aged 30Ā years or younger and 5.9% for women over the age of 30Ā years at the time of sterilization. However, after permanent hysteroscopic sterilization, the opportunity to undergo sterilization reversal seems unlikely. Some requests for sterilization reversal were followed by in vitro fertilization (IVF) procedures. However, the impact of the EssureĀ® coil on IVF outcomes and pregnancy course is uncertain [22, 23]. Therefore, we thought of developing a reversible and immediately effective hysteroscopic sterilization method that is safe and effective. In the present article, we describe a micro-barrier contraception method by using shape memory alloy that can be easily inserted in the interstitial fallopian tube in an outpatient setting. Our proposed method may result in a low-cost, non-hormonal, long-term, reversible, and discreet method of contraception for women.

The presentation of hypothesis

The manufacture of the hysteroscopic sterilization device.

The device consists of an umbrella supporter made of NiTi alloy and an umbrella fabric made of a waterproof polyurethane-like membrane. Our device is 8Ā mm in length and 1.5Ā mm in diameter when closed. Once opened, the diameter of the umbrella fabric expands to 6.5Ā mm. One end (head) of the device is covered with a semi-soft cap made of a biodegradable material. At the other end (tail), there is a small fibre intended to facilitate removal. The NiTi alloy is covered with two coatings. The first coating is silicon dioxide (SiO2) applied using the solā€“gel method to avoid toxic Ni release. The second coating is a macromolecular substance with high biological stability to prevent stimulation of epithelial tissue of the oviduct growth. The candidates for the second coating include poly (dimethylacrylamide) (PDMAA) and poly (2-ethyloxazoline) (PEtOx), which represent anti-adhesive properties and can be applied as coatings by a photochemical grafting method to reduce the unspecific extracellular matrix-mediated adhesion of fibroblasts to implant surfaces [24].

The device can change its size according to the temperature.

NiTi alloy is a SMA, which ā€œremembersā€ its original and forged shape at a specified temperature. Basically, SMA presents two well-defined phases: austenite and martensite. The martensite phase consists of a SMA only at low temperature range. Martensite is soft and can be easily deformed by stress. When the temperature rises to austenite activation temperature (As, the lowest temperature at which the SMA starts to change its shape), the SMA recovers its shape toward the original and forged shape gradually and completely when the temperature reaches austenite final temperature (Af). Then, when temperature decreases, austenite starts to change its shape to martensite at martensite start temperature (Ms) and completes the transformation at martensite final temperature (Mf) [14, 25]. The device is like an umbrella that stays collapsed before insertion; it is activated by body temperature and subsequently opened by the force of shape memory (see FigureĀ 1). The umbrella fabric is supported by several axes joined with a thin circular ring and covered with the waterproof polyurethane-like membrane. The opened device anchors in the interstitial fallopian tube as a barrier and prevents the sperm cells from coming in contact with the ova.

Figure 1
figure 1

Illustration of the structure and working principle of the device. (A) The device before insertion into the tubal interstitial portion, like a folded umbrella which minimizes its size in diameter and subsequently facilitates the insertion of the device; (B) The device after the insertion into the interstitial portion, like an unfolded umbrella; (C) Coronal section view, the device is placed at the interstitial portion of the tube, The device is anchored in the right place and the passage through the tube is completely blocked. 1. A semi-soft hat; 2. A waterproof membrane; 3. Guild rod; 4. A small hole; 5. The supporter of the shape memory umbrella; 6. A thin circular rim to cut into the interstitial myometrium for fixation.

The device can be placed hysteroscopically.

According to our hypothesis, when the device is inserted via hysteroscopy, the temperature of the running distension fluid into the uterine cavity is low; thus, the device maintains its collapsed shape. After it is inserted into the interstitial tubal lumen, the device temperature rises to body temperature; consequently, the device ā€œremembersā€ and returns to its originally forged shape. The rim of the open device will incise into the interstitial myometrium during the process of unfolding. The rim is very thin, which facilitates the cut. Once the incision process is finished, the device is fixed to the interstitial myometrium. The open device will obstruct the tube completely.

The device is a reversible sterilization method.

The device anchors in a very narrow part of the tube and little tissue is damaged by the thin rim. Because the device is coated with a highly stable macromolecular substance, it is biologically inactive and cannot induce tissue growth or encapsulation. When the patient wishes to reverse sterilization, a liquid at low temperature is perfused into the uterine cavity. Then device tail can be used for its removal under hysteroscopy. Owing to litter damage caused by the thin rim (diameter: 0.05-0.1Ā mm), the scars in the fallopian tube will be very small. The fallopian tube will revert to its function after the device is removed.

Therefore, the design of the safe, reversible, and immediately effective sterilization device was achieved. We obtained a national patent in China for the invention of the sterilization device described herein. The application number of the patent is ZL200810030905 [26] (see Additional file 1: supplemental document S1 and Additional file 2: supplemental document S2).

Testing the hypothesis

The core for testing our hypothesis is to successfully manufacture the barrier contraceptive device by using shape memory material and to test the device activation and modification under different temperatures simulating a normal range of body temperatures at our material laboratory. The testing process involved the following steps.

Step 1, to manufacture the device parts, including the following:

  1. (1)

    Manufacture the NiTi alloy adjust the NiTi alloy As to 10 degrees centigrade and Af to 35 degrees centigrade by changing the mixture proportions of Ni and Ti and by applying a thermal treatment technique in the laboratory;

  2. (2)

    Manufacture the NiTi alloy supporter;

  3. (3)

    Cover with both coatings and test the efficiency and biocompatibility of the coatings;

  4. (4)

    Manufacture the waterproof membrane made of poly(dimethylacrylamide) (PDMAA) or poly(2-ethyloxazoline) (PEtOx);

  5. (5)

    Assemble the device supporter made of NiTi alloy and the waterproof membrane.

Step 2, to manufacture 6 devices and test the effect of the transformation from the closed shape to the opened shape under simulated temperatures (under water) in the material laboratory.

Step 3, to test the placement of the device and the effect of the transformation hysteroscopically under simulated temperatures in a surgically excised uterus: placing the device into the interstitial portion in a surgically excised uterus (with interstitial portions) by using the hysteroscopic catheterization technique.

Step 4, to conduct prospective, observational animal experiments and then clinical studies to assess device safety, efficacy and reversibility, that is, we will continue to test the device and collect data on biocompatibility, successful placement rate, obstruction rate, the contraceptive effect and reversal of contraceptive effect, and any complications (such as nickel allergies, infection, pain, and device displacement) in animal experiments using goats and then a preliminary clinical trial with a small sample size (about 10 to 15 patients: age ā‰„ā€‰20Ā years, gravity ā‰„ā€‰1, without infertility). Necessarily, we will adjust and improve the design of the device. If the preliminary clinical trial presents the device is safe and effective, a large scale clinical trial (at least 50 to 100 patients) will be conducted to evaluate the device comprehensively.

Implications of the hypothesis

It is predicted that the total world population will reach 8.9 billion in 2050 and more than 26 billion couples will need contraceptives in the next half century. Although steady progress in hormonal and non-hormonal modern contraceptive research has been achieved over the past 50Ā years, the contraceptives available today have all kinds of adverse effects and are not suitable for all users. A need to expand contraceptive methods still exists [27, 28]. Our efforts to develop a novel contraceptive device with special characteristics make great sense. Two of the largest advantages of this contraception method are reversibility and immediate effectiveness. EssureĀ®, the most promising intratubal device available, consists of a stainless steel inner coil, an outer coil of nitinol, and polyethylene terephthalate (PET) fibres. After insertion into the interstitial portion of each fallopian tube by hysteroscopic guidance, the outer coil expanded and anchored the device to the fallopian tube. Over the next few weeks, fibrotic tissue growth around the device by PET stimulating results in complete tubal occlusion [29, 30]. At last, tubal occlusion and proper positioning must be confirmed at 3Ā months postprocedure by performing a HSG, or a pelvic radiograph for both sterilization systems [30]. Owing to the irreversible damage of the tube, the sterilization methods are permanent. If patients wish to conceive again, they must turn to IVF. Obviously, our reversible device is more practical and allows patients to change their minds concerning sterilization. Our device is the less invasive modality. Our device, with a uniquely designed shape, is 8Ā mm in length, equivalent to the interstitial portion of fallopian tube. There is no pressure from the oviduct peristalsis and the device is relatively unlikely to be excluded by this force. The difficulty of placement and possibility of perforation are lower. However, EssureĀ®, for example, is 4Ā cm long and anchors to a 3-cm segment of the tube. Bilateral tube placement would fail if there is adhesion in the isthmus or ampulla portions of the fallopian tube. In addition, several studies reported the use of EssureĀ® devices in proximal tubal occlusion in subfertile women with hydrosalpinges before IVF [31] and receiving IVF procedures with the presence of the EssureĀ®[32]. Although, researchers favoured the outcome, the sample size was still very small. Further, there is concern that intrauterine coils of EssureĀ® could interfere with subsequent IVF procedures [29]. Therefore, a safe and effective hysteroscopic sterilization method is needed urgently.

In theory, the development consists of attractive advantages such as the long-term, easy-placement, reversible and immediately effective. If it is really effective, it may have significant repercussions for numerous women worldwide. However, the device obstructs the fallopian tube mechanically by a waterproof polyurethane-like membrane rather than destroys the cavity of tube and makes a permanent obstruction by the formation of fibrotic tissue as EssureĀ®. Theoretically, our device would have a lower contraceptive success rate. Therefore, the corrosion resistance, stability and tenacity of the waterproof membrane need further research. In addition, whether the scars in the fallopian tube caused by the device placement could lead to impaired tubal motility and, thereby, impact on fertility negatively after removal of the devices also is an important part of our study in the future. For these reasons, repeated animal experiments and subsequent clinical studies are now needed to attest the safety and efficiency of the novel contraceptive device and improve it continuously.

References

  1. CastaƱo PM, Adekunle L: Transcervical sterilization. Semin Reprod Med. 2010, 28: 103-109.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  2. Abbott J: Transcervical sterilization. Curr Opin Obstet Gynecol. 2007, 19: 325-330.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  3. Smith RD: Contemporary hysteroscopic methods for female sterilization. Int J Gynaecol Obstet. 2010, 108: 79-84.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  4. Kraemer DF, Yen PY, Nichols M: An economic comparison of female sterilization of hysteroscopic tubal occlusion with laparoscopic bilateral tubal ligation. Contraception. 2009, 80: 254-260.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  5. Maubon AJ, Thurmond AS, Laurent A, Honiger JE, Scanlan RM, Rouanet JP: Selective tubal sterilization in rabbits: experience with a hydrogel combined with a sclerosing agent. Radiology. 1994, 193: 721-723.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  6. Bigolin S, Fagundes DJ, Rivoire HC, Fagundes AT, Fagundes AL: Transcervical hysteroscopic sterilization using cyanoacrylate: a long-term experimental study on sheep. J Obstet Gynaecol Res. 2009, 35: 1012-1018.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  7. Bigolin S, Fagundes DJ, Rivoire HC, Fagundes AT, SimƵes R, SimƵes Mde J: Hysteroscopic sterilization with occlusion of sheep uterine tube using n-butyl-2-cyanoacrylate adhesive. Acta CirBras. 2007, 22: 401-406.

    Google ScholarĀ 

  8. Jensen JT, Rodriguez MI, Liechtenstein-ZƔbrƔk J, Zalanyi S: Transcervical polidocanol as a nonsurgical method of female sterilization: a pilot study. Contraception. 2004, 70: 111-115.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  9. McLemore R, Kim EJ, Brandon TA, Aerni G, Roy KH, Vernon BL: Tubal sterilization with a waterborne polyethylene glycol in situ cross-linking material: a minimally invasive approach. Fertil Steril. 2005, 83 (Suppl 1): 1284-1292.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  10. Rehan M, Coleman J, Olabi AG: Novel implant for transcervical sterilization. J Biosci Bioeng. 2010, 110: 242-249.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  11. Binkert CA, Pavcnik D, Andrews RT, Loriaux MM, Uchida B, Brountzos EN, Rƶsch J: Fallopian tube occlusion with use of a small intestine submucosa device: evaluation in a rabbit model. J Vasc Interv Radiol. 2004, 15: 609-613.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  12. Tang S, Zhang CY, Huang MN, Luo YF, Liang ZQ: Fallopian tube occlusion with a shape memory polymer device: evaluation in a rabbit model. Contraception. 2013, 87: 235-241.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  13. Lendlein A, Langer R: Biodegradable, elastic shape-memory polymers for potential biomedical applications. Science. 2002, 296: 1673-1676.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  14. Tarniţă D, Tarniţă DN, BĆ®zdoacă N, MĆ®ndrilă I, Vasilescu M: Properties and medical applications of shape memory alloys. Rom J Morphol Embryol. 2009, 50: 15-21.

    PubMedĀ  Google ScholarĀ 

  15. Yeung KW, Poon RW, Chu PK, Chung CY, Liu XY, Lu WW, Chan D, Chan SC, Luk KD, Cheung KM: Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials. J Biomed Mater Res A. 2007, 82: 403-414.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  16. Ozeki K, Yuhta T, Aoki H, Fukui Y: Inhibition of Ni release from NiTi alloy by hydroxyapatite, alumina, and titanium sputtered coatings. Biomed Mater Eng. 2003, 13: 271-279.

    CASĀ  PubMedĀ  Google ScholarĀ 

  17. Wang LG, Qiu Y, Fan YJ, Li XY, Han XJ: Reversible contraceptive effect of the oviduct plug with nickel-titanium shape memory alloy and silicone rubber in rabbits. Contraception. 2011, 83: 373-377.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  18. Ubeda A, Labastida R, Dexeus S: Essure: a new device for hysteroscopic tubal sterilization in an outpatient setting. Fertil Steril. 2004, 82: 196-199.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  19. Cleary TP, Tepper NK, Cwiak C, Whiteman MK, Jamieson DJ, Marchbanks PA, Curtis KM: Pregnancies after hysteroscopic sterilization: a systematic review. Contraception. 2013, 87: 539-548.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  20. Basinski CM: A review of clinical data for currently approved hysteroscopic sterilization procedures. Rev Obstet Gynecol. 2010, 3: 101-110.

    PubMed CentralĀ  PubMedĀ  Google ScholarĀ 

  21. Wittmer MH, Famuyide AO, Creedon DJ, Hartman RP: Hysterosalpingography for assessing efficacy of Essure microinsert permanent birth control device. AJR Am J Roentgenol. 2006, 187: 955-958.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  22. Hillis SD, Marchbanks PA, Tylor LR, Peterson HB: Poststerilization regret: findings from the United States Collaborative Review of Sterilization. Obstet Gynecol. 1999, 93 (6): 889-895.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  23. Curtis KM, Mohllajee AP, Peterson HB: Regret following female sterilization at a young age: a systematic review. Contraception. 2006, 73: 205-210.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  24. Aliuos P, Sen A, Reich U, Dempwolf W, Warnecke A, Hadler C, Lenarz T, Menzel H, Reuter G: Inhibition of fibroblast adhesion by covalently immobilized protein repellent polymer coatings studied by single cell force spectroscopy. J Biomed Mater Res A. 2013, 102: 117-127.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  25. Pena J, Solano E, Mendoza A, Casals J, Planell JA, Gil FJ: Effect of the M(s) transformation temperature on the wear behaviour of NiTi shape memory alloys for articular prosthesis. Biomed Mater Eng. 2005, 15: 289-293.

    CASĀ  PubMedĀ  Google ScholarĀ 

  26. State Intellectual Property Office of the People's Republic of China. http://www.pss-system.gov.cn/sipopublicsearch/ensearch/searchEnHomeIndexAC.do,

  27. Sitruk-Ware R, Nath A, Mishell DR: Contraception technology: past, present and future. Contraception. 2013, 87: 319-330.

    ArticleĀ  PubMed CentralĀ  PubMedĀ  Google ScholarĀ 

  28. Sitruk-Ware R: Contraception: an international perspective. Contraception. 2006, 73: 215-222.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  29. Valle RF, Carignan CS, Wright TC, STOP Prehysterectomy Investigation Group: Tissue response to the STOP microcoil transcervical permanent contraceptive device: results from a prehysterectomy study. Fertil Steril. 2001, 76: 974-980.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  30. Palmer SN, Greenberg JA: Transcervical sterilization: a comparison of essure(r) permanent birth control system and adiana(r) permanent contraception system. Rev Obstet Gynecol. 2009, 2: 84-92.

    PubMed CentralĀ  PubMedĀ  Google ScholarĀ 

  31. Mijatovic V, Veersema S, Emanuel MH, Schats R, Hompes PG: Essure hysteroscopic tubal occlusion device for the treatment of hydrosalpinx prior to in vitro fertilization-embryo transfer in patients with a contraindication for laparoscopy. Fertil Steril. 2010, 93: 1338-1342.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  32. Kerin JF, Cattanach S: Successful pregnancy outcome with the use of in vitro fertilization after Essure hysteroscopic sterilization. Fertil Steril. 2007, 87: 1212-e1-1212.e4

    ArticleĀ  PubMedĀ  Google ScholarĀ 

Download references

Acknowledgements

This study was supported by the National Natural Science Foundation (Grant No. 81170609). We thank Editage for the assistance of the language corrections of the manuscript.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Dabao Xu.

Additional information

Competing interests

The authors declare that they have no competing interests.

Authorsā€™ contributions

XB wrote the manuscript. XDB and ALA conceived the study. ZKA, XDB and ALA participated in its design and helped to draft the manuscript. All authors read and approved the final manuscript.

Electronic supplementary material

Authorsā€™ original submitted files for images

Below are the links to the authorsā€™ original submitted files for images.

Authorsā€™ original file for figure 1

Rights and permissions

This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Xu, B., Zhu, Ka., Xu, D. et al. Management of long-term and reversible hysteroscopic sterilization: a novel device with nickel-titanium shape memory alloy. Reprod Biol Endocrinol 12, 61 (2014). https://doi.org/10.1186/1477-7827-12-61

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/1477-7827-12-61

Keywords